SX50

Technical Support

Icon Caret Product Introduction

SX50

Ultra Heavy Duty Cavity Wall Lintel 

Cavity: 50-65mm 

Inner Leaf: 100mm

Outer Leaf: 100mm

Should be laterally restrained and propped during installation.

 

Features  

  • DoP Ref: BIR538CPR2014
  • Lack of baseplate and factory fitted insulation reduces thermal bridging
  • Supergalv coating offers superior life expectancy

 

Length 750-4200 4350-4800 4950-5400 5550-5700 5850-6000 6150-6300 6450-6600
L (kN) 90 80 70 65 55 50 45
W (kg/m) 41.7 41.7 41.7 41.7 41.7 41.7 41.7
H (mm) 213 213 213 213 213 213 213

(L) Load SWL/UDL value (W) Weight (H) Height 