Product Range
Timber Frame Lintels
Product Sub-range
150-165mm Cavity
Product Type
Standard Duty Timber Frame Lintel - 100mm Outer Leaf
European Standard/ETA
BS EN845-2:2013+A1:2016
Test Standard
EN846-9:2000/2016
Notified Body
Lucideon Ltd (NB 1289)
Material
Mild Steel S275JR to BS EN10025-2:2004
Coating/Finish/Colour
65µm Hot Dip Galvanized to BS EN ISO 1461:2009
Thermal Performance
Contact us for information
Insulation
Expanded Polystyrene - BREEAM rating A+
Fire Rating
60 mins (with 2 coat plaster finish)
1. Installation requirement
Bed fully on bricklaying mortar
2. Installation requirement
Must be used with a cavity tray - External walls only
3. Installation requirement
Use lintel clips at <600mm intervals, not more than 225mm from each end
4. Installation requirement
Lintels over 1200mm must be propped until masonry is fully loaded and cured.
5. Installation requirement
150mm Minimum end Bearing
1. Features
Supergalv coating offers superior life expectancy
2. Features
Post-fabrication galvanizing leaves no surface with inferior paint protection
3. Features
Structural grade steel to EN10025
Option 1
Alternative material options: Ultragalv coating (150µm), Stainless Steel 1.4301 (304)
Option 2
Outer Leaf Options: No rainwater drip (ND), Render mesh (MF)